Program Mode
The following Tables list the data which is automatically programmed for each Format that can be selected in address
50. The addresses shown in each Table contain the event code Setting data which is automatically programmed by
the 411UD. To change the value, key in the new digits and then press the [ENTER/STORE] key to save the new
value. Use the Up and Down Arrow keys to increment to the next address or decrement to the previous address.
Ademco Contact ID Format Secondary Central Station Event Codes
If E is entered for address 50, the following data is automatically programmed for the Secondary Central Station
phone number event codes. Enter '000' for the Setting to disable the report to the Central Station.

Ademco Contact ID Format - Secondary

TABLE 3-4:
Address
202 - 204
205 - 207
208 - 210
211 - 213
214 - 216
217 - 219
220 - 222
223 - 225
226 - 228
229 - 231
232 - 234
235 - 237
238 - 240
241 - 243
244 - 246
247 - 249
250 - 252
253 - 255
256 - 258
4+2 Standard and 4+2 Express Formats Secondary Central Station Event Codes
If 1, A or C is entered for address 50, the following data is automatically programmed for the Secondary Central Sta-
tion phone number event codes. Enter '00' for the Setting to disable the report to the Central Station.

4+2 Standard and 4+2 Express Formats - Secondary

TABLE 3-5:
Address
202 - 203
204 - 205
206 - 207
208 - 209
210 - 211
212 - 213
214 - 215
216 - 217
32
Description
Secondary # Input Channel 1 Active Event Code
Secondary # Input Channel 2 Active Event Code
Secondary # Input Channel 3 Active Event Code
Secondary # Input Channel 4 Active Event Code
Secondary # Input Channel 1 Fault Event Code
Secondary # Input Channel 2 Fault Event Code
Secondary # Input Channel 3 Fault Event Code
Secondary # Input Channel 4 Fault Event Code
Secondary # Phone Line 1 Voltage Fault Event Code
Secondary # Phone Line 2 Voltage Fault Event Code
Secondary # Phone Number 1 Comm. Fault Event Code
Secondary # Phone Number 2 Comm. Fault Event Code
Secondary # System Off Normal Fault Code
Secondary # System Test Message
Secondary # System Abnormal Test Message
Secondary # Upload/Download Request Code
Secondary # Upload Successful Code
Secondary # Download Successful Code
Secondary # Upload/Download Failed Code
Description
Secondary # Input Channel 1 Active Event Code
Secondary # Input Channel 2 Active Event Code
Secondary # Input Channel 3 Active Event Code
Secondary # Input Channel 4 Active Event Code
Secondary # Input Channel 1 Fault Event Code
Secondary # Input Channel 2 Fault Event Code
Secondary # Input Channel 3 Fault Event Code
Secondary # Input Channel 4 Fault Event Code
411UD
Document #50759 Rev. E 12/09/2008 P/N 50759:E
Channel/
Setting
Input #
110
001
373
002
200
003
301
004
380
001
380
002
380
003
380
004
351
000
352
000
354
001
354
002
308
000
602
000
608
000
411
000
416
000
412
000
413
000
Setting
11
FF
83
92
F1
F2
F3
F4

Hide quick links: