Inverter Keypad Operation - Hitachi L200 Series Quick Reference Manual

Single-phase input 200v class; three-phase input 200v class; three-phase input 400v class
Hide thumbs Also See for L200 Series:
Table of Contents

Advertisement

Inverter Keypad Operation

Run Key Enable LED
Program/Monitor LED
HITACHI
RUN
FUNC.
Run Key
Function Key
• Run/Stop LED – ON when the inverter output is ON and the motor is
developing torque, and OFF when the inverter output is OFF (Stop
Mode).
• Program/Monitor LED – ON when the inverter is ready for parame-
ter editing (Program Mode). It is OFF when the parameter display is
monitoring data (Monitor Mode).
• Run Key Enable LED – ON when the inverter is ready to respond to
the Run key, OFF when the Run key is disabled.
• Run Key – Press this key to run the motor (the Run Enable LED must
be ON first). Parameter F004, Keypad Run Key Routing, determines
whether the Run key generates a Run FWD or Run REV command.
• Stop/Reset Key – Press this key to stop the motor when it is running
(uses the programmed deceleration rate). This key will also reset an
alarm which has tripped.
• Potentiometer – Allows an operator to directly set the motor speed
when the potentiometer is enabled for output frequency control.
• Potentiometer Enable LED – ON when the potentiometer is enabled
for value entry.
(continued, next page...)
Parameter Display
Run/Stop LED
Hz
5 0.0
A
RUN
PRG
STOP
RESET
2
STR
1
Up/Down Keys
Serial Port
Power LED
Alarm LED
POWER
ALARM
Display Units LEDs
Potentiometer
Enable LED
Potentiometer
Stop/Reset Key
Store Key
5
Hertz
Amperes

Advertisement

Table of Contents
loading

Table of Contents