Item
Input
Freq.
Operator panel Up and Down keys / Value settings
signal
setting
Potentiometer
External signal
*6
FWD/
Operator panel Run/Stop (Forward/Reverse run change by command)
REV
External signal Forward run/stop, Reverse run/stop
Run
Intelligent input
terminal
Output
Intelligent output
signal
terminal
Frequency monitor
Alarm output contact
Other functions
Protective function
Operat-
Temperature
ing
Humidity
Environ
ment
Vibration *9
Location
Coating color
Options
Standards
Marking
General Specifications
Analog setting
0 to 10 VDC (input impedance 10k Ohms), 4 to 20 mA (input
impedance 250 Ohms), Potentiometer (1k to 2k Ohms, 2W)
FW (forward run command), RV (reverse run command), CF1~CF4
(multi-stage speed setting), JG (jog command), 2CH (2-stage accel./
decel. command), FRS (free run stop command), EXT (external
trip), USP (startup function), SFT (soft lock), AT (analog current
input select signal), RS (reset), PTC (thermal protection), STA (start,
3-wire interface), STP (stop, 3-wire interface), F/R (FW/RV 3-wire
interface), UP (remote control Up function, motorized speed pot.),
DWN (remote control Down function, motorized speed pot.), OPE
(operator control)
RUN (run status signal), FA1,2 (frequency arrival signal), OL
(overload advance notice signal), OD (PID error deviation signal),
AL (alarm signal)
PWM output; Select analog output frequency monitor, analog output
current monitor or digital output frequency monitor
ON for inverter alarm (1C contacts, both normally open or closed
avail.)
AVR function, curved accel/decel profile, upper and lower limiters,
16-stage speed profile, fine adjustment of start frequency, carrier
frequency change (0.5 to 16 kHz) frequency jump, gain and bias
setting, process jogging, electronic thermal level adjustment, retry
function, trip history monitor
Over-current, over-voltage, under-voltage, overload, extreme high/
low temperature, CPU error, memory error, ground fault detection at
startup, internal communication error, electronic thermal
Operating (ambient): -10 to 50°C (*7) / Storage: -25 to 70°C (*8)
20 to 90% humidity (non-condensing)
2
5.9 m/s
(0.6G), 10 to 55 Hz
Altitude 1,000 m or less, indoors (no corrosive gasses or dust)
Light purple, cooling fins in base color of aluminum
Remote operator unit, copy unit, cables for the units, dynamic
braking unit, braking resistor, AC reactor, DC reactor, noise filter,
DIN rail mounting
EN 61800-3 EMC Guidelines in connection with optional line filter
modules in line with installation guidelines, EN 50718 Low-Voltage
Guideline, UL, cUL
UL, cUL