Forward Run/Stop and Reverse Run/Stop Commands:
When you input the Run command via the terminal [FW], the inverter executes the
Forward Run command (high) or Stop command (low). When you input the Run
command via the terminal [RV], the inverter executes the Reverse Run command (high)
or Stop command (low).
Option
Terminal
Function Name
Code
Symbol
00
FW
Forward Run/Stop
01
RV
Reverse Run/Stop
C_01, C_02, C_03, C_04,
Valid for inputs:
C_05
Required settings:
A_02 = 01 (terminal control)
A_02 = 02 (keypad control)
Notes:
When the Forward Run and Reverse Run
commands are active at the same time, the inverter
enters the Stop Mode.
When a terminal associated with either [FW] or
[RV] function is configured for normally closed,
the motor starts rotation when that terminal is
disconnected or otherwise has no input voltage.
L100-M Series inverters can also use [FW] and [RV] inputs in real time to determine the
direction of rotation for the keypad Run key. This requires setting A_02=02 (keypad
control) and Run Key Routing F_04 = 02 (terminal). The operation is shown below.
[FW]
[RV]
Run key
Stop key
Motor
rotation
State
ON
Inverter is in Run Mode, motor runs forward
OFF
Inverter is in Stop Mode, motor stops
ON
Inverter is in Run Mode, motor runs reverse
OFF
Inverter is in Stop Mode, motor stops
1
0
1
0
1
0
1
0
forward
+
L100-M Inverter
Description
Example (default input configuration shown—
see Chapter 3 in L100 Instruction Manual):
RV
L
5
4
3
2
for
-MFR2
models
See I/O specs in the L100 Instruction Manual
reverse
23
FW
1
P24
for
-MFU2
models
t