Hitachi L100-M Series Addendum Manual page 5

Hide thumbs Also See for L100-M Series Addendum:
Table of Contents

Advertisement

Model-specific tables for 100V class inverters
The following table is specific to L100-M Series inverters. Note that "General Specifica-
tions" on page 6 apply to all L100-M inverters. Footnotes for both tables follow the table
below.
Item
L100-M invert-
CE version
ers, 100V models
UL versions
Applicable motor size *2
Rated capacity (230V) kVA *10
Rated input voltage
Rated input
1-phase
current (A)
Rated output voltage *3
Rated output current (A)
Efficiency at 100% rated output (%)
Watt loss,
at 70% output
approximate (W)
at 100% output
Braking
Dynamic
braking, approx.
% torque, (short
time stop from
50 / 60 Hz) *5
DC braking
Weight
100V Class Specifications
002MFU2,
002MFR2
kW
0.2
HP
0.25
0.5
1-phase: 100V to 120V, +5/–10%; 50/60 Hz ±5%
5.5
3-phase 0 to 230V (corresponding to 2 times input voltage)
1.4
92.2
13
17
Capacitive feedback type, dynamic braking unit and braking
resistor optional, individually installed
Variable operating frequency, time, and braking force
kg
1.1
lb
2.4
L100-M Inverter
004MFU2,
007MFU2,
004MFR2
007MFR2
0.4
0.75
0.5
1.0
10
2.6
93.2
94.8
21
29
100%: ≤ 50Hz
50%: ≤ 60Hz
1.2
2.6
5
1
1.6
16
4.0
31
41
1.5
3.3

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents