Configuring Drive Parameters
C" Group: Intelligent Terminal Functions
The intelligent input terminals for L100-M Series inverters have 21 possible option
assignments.
Func.
Name /
Code
SRW Display
C_01 Terminal [1] function
IN-TM 1
C_02 Terminal [2] function
IN-TM 2
C_03 Terminal [3] function
IN-TM 3
C_04 Terminal [4] function
IN-TM 4
C_05 Terminal [5] function
IN-TM 5
L100-M Series inverters have the 15 intelligent input option codes of standard L100
inverters, but with the model series restriction noted below:
Option
Terminal
Code
Symbol
19
PTC
"C" Function
Description
Select function for terminal [1]
21 options (see next section)
FW
Select function for terminal [2]
21 options (see next section)
RV
Select function for terminal [3]
21 options (see next section)
AT
Select function for terminal [4]
21 options (see next section)
USP
Select function for terminal [5]
21 options (see next section)
2CH
Input Function Summary Table
Function Name
PTC Thermistor
ON
Thermal Protection
–MFR2 series only
OFF
Run
Mode
–MFU2
Edit
00
[FW]
01
[RV]
16
[AT]
13
[USP]
18
[RS]
Description
When a thermistor is connected to terminals [5]
and [L], the inverter checks for over-
temperature and will cause trip event and turn
OFF output to motor
A disconnect of the thermistor causes a trip
event, and the inverter turns OFF the motor
Defaults
–MFR2
Units
00
[FW]
01
[RV]
02
[CF1]
03
[CF2]
18
[RS]