Motorola AP-51XX Product Reference Manual page 669

Table of Contents

Advertisement

• If the existing and update firmware files are the same, the firmware will not get updated.
To configure the DHCP Server for automatic updates:
1. Set the Windows DHCP Server and access point on the same Ethernet segment.
2. Configure the Windows based DHCP Server as follows:
a. Highlight the Server Domain Name (for example, apfw.motorola.com). From the
menu, select
b. Create a new vendor class. For example, AP51xx Options.
c. Enter the vendor class Identifier MotorolaAP.51xx-V1-1-1. Enter the value in ASCII
format, the server converts it to hex automatically. Use the chart below to determine
which vendor class ID to use based on the firmware.
d. From the
e. Add the following 3 new options under AP51xx Options class:
Access point TFTP Server IP Address
(Note: Use any one option)
Access point Firmware File Name
Access point Config File Name
(Note: Use any one option)
f. Highlight
g. Go to the
options mentioned in the table above and enter a value for each option.
3. Copy the firmware and configuration files to the appropriate directory on the TFTP Server.
4. Restart the access point.
5. While the access point boots, verify the access point:
Define Vendor
Classes.
AP Firmware
Vendor Class ID
1.1 (or older)
SymbolAP.5131-V1-1
1.1.1.x
SymbolAP.51xx-V1-1-1
1.1.2.x
MotorolaAP.51xx-V1-1-2
2.0
MotorolaAP.51xx-V2-0-0
Action
menu, select
Scope Options
from the tree and select
Advanced
tab. From under the Vendor Class AP51xx Options, check all three
Set Predefined
Options.
Code
Data type
181
IP address
186
String
187
String
129
String
188
String
Configure
Usage Scenarios
Action
Options.