11.2.3 Angle Position of the Burner

38
The burner 4 must be at an angle of approx. 90° to the thread
positioned by the thread deflector 3.
1
2
Caution Risk of Injury !
Turn the main switch off.
Set the angle position of the burner only with the main switch turned
off.
Remove the finger guard 2 after loosening the mounting screws.
The clamping screws 1 are readily accessable.
Loosen the clamping screws 1 slightly.
Set the correct angle position by swinging the burner.
Tighten clamping screws 1.
Attach the finger guard 2 again.
Caution Risk of Injury !
After completing the setting work it is essential that the finger guard be
attached again.