1
Align the feed plate 1 centered to the needle:
In the crosswise direction (Querrichtung):
In the lengthwise direction (Längsrichtung):
Setting the width of the movement of the feed plate 1:
In the crosswise direction (Längsrichtung):
In the lengthwise direction (Querrichtung):
Loosen the nuts 5 and 7.
By turning the threaded rod 6 align the feed plate 1 in the
crosswise direction centered to the needle.
Tighten the nuts 5 and 7.
Loosen screw 9 slightly.
By turning the eccentric 10 align the feed plate 1 in the lengthwise
direction centered to the needle.
Tighten screw 9.
Loosen the nut 8 slightly.
Set the width of the movement in the crosswise direction by sliding
the link in the slot.
Tighten nut 8.
Loosen screw 9.
Set the width of the movement in the lengthwise direction by
sliding the link in the slot.
Attention !
Thereby do not change the setting of the eccentric 10.
Tighten screw 9.
5
6
7
9
10
8