10. Shut Off Devices
10.1 Transport Levers for Lengthwise and Crosswise Movement (Switches b09, b16)
1
28
The setting of the switches b09 and b16 is only necessary by units
with an "open guide curve".
"Open guide curves" are used for seam formations where the seam
end and seam beginning are at different positions.
Through the straight section 1 of the curve runs the transport levers for
the lengthwise and crosswise movement are moved back into the
initial position after completion of the seam.
The movement occurs in the base position of the curve disk via the
pneumatic cylinders 2 and 3.
The base position (seam beginning position) of both transport levers is
scanned via switches b09 and b16.
2
3