Position Of The Limit Switch In The Slotted Hole; Distance Between Switching Screw And Limit Switch; Stop Guide For Transport Carriage - DURKOPP ADLER 745-34-2 Installation Instructions Manual

Sewing unit for runstitching of piped flap and welt pocket openings and pocket corners
Table of Contents

Advertisement

3.1.1

Position of the limit switch in the slotted hole

3.1.2

Distance between switching screw and limit switch

3.1.3
Stop for transport carriage
Checking
Unscrew screws 7 and take off the covering cap 6.
Check the position of the limit switch 1 in the slotted hole 2.
Correction
Loosen the counter nut at the limit switch 1.
Set the limit switch in the slotted hole 2 as described in
chapter 4.5.
Tighten the counter nut again.
Attention: Danger of breakage !
After operations on the limit switch always check the distance to the
switching screw.
Checking
Unscrew screws 7 and take off the covering cap 6.
Push the transport carriage 4 to the very back.
Check the distance of 1 mm between limit switch 1 and switching
screw 3.
Correction
Pull the transport carriage 4 to the front until the switching screw 3
is accessible laterally.
Loosen the counternut at the switching screw.
Adjust the height of screw 3.
Distance between switching screw and fastening surface = 16 mm.
Tighten the counternut.
Push the transport carriage 4 to the very back.
Set a distance of 1 mm between limit switch 1 and screw 3.
Checking
Push the transport carriage 4 to the back until the surface of the
switching screw 3 stands centrical above the limit switch 1.
Check whether in this transport carriage position the distance
between the stop 5 and the transport carriage amounts to 2 mm.
Correction
Push the transport carriage to the back until the surface of the
switching screw 3 stands centrical above the limit switch 1.
Loosen counternut 8.
Approach the stop 5 to the transport carriage by 2 mm.
Tighten counternut 8.