6. Electrical connection

6.1 General

6.2

Checking the mains voltage

6.3

Connecting the sewing drive

6.3.1

Connecting the clutch motor

6.3.2

Connecting the coupling-positioning actuator

18
Caution !
All work on the electrical equipment of this special sewing machine
may only be carried out by qualified electricians or other appropriately
trained persons.
The mains plug must be removed.
Caution !
The mains voltage must coincide with the rated voltage specified on
the model-identification plate.
Lay the connection cable from the main switch through the cable
conduit to the sewing drive and connect it to the sewing drive. See
connection diagram 9800 169002 B (in the connection pack) or the
circuit diagram on the clutch motor.
Lay the mains cable from the main switch back through the cable
conduit and attach to the mains-lead cleat.
Lay the connection cable from the motor-protection switch through
the cable conduit to the sewing drive and connect it to the sewing
drive.
See connection diagram 9800 129002 B (in the connection pack) or
the circuit diagram on the coupling-positioning actuator.
Lay the mains cable from the main switch back through the cable
conduit and attach to the mains-lead cleat.
Plug the cable from the set-point generator into socket b80 of the
drive control. See figure page 20.