Rf Address Code Setting; Testing Rf Transmission - Salus RT500RF Instruction Manual

Programmable
Hide thumbs Also See for RT500RF:
Table of Contents

Advertisement

4
5

RF Address Code Setting

If there is another user nearby, e.g. in the next house, your
receiver may be fault triggered by their transmitter. You may
select a different RF address code to prevent this. The
receiver can only respond to RF transmissions with the same
address code setting as its own address code.
1. To adjust address code of Receiver, simply
push up one or more of the 5 dip switch levers.
The leavers are numbered 1 to 5 from left to right.
2. To adjust address code of Control Centre, remove
one or more of the jumper caps located on the
back of the unit, labeled 1,2,3,4,5.
3. You must press reset on the control centre after
altering the address code.
Caution :
1. Address code of Control Centre must be the
same as address code of Receiver. For any
jumper cap removal of address code # in
Control Centre, the same address code # of
Receiver must be put to the UP position.
2. Disconnect AC power and
remove batteries
prior to adjusting
address code.
Address Code Dip
Switch Leavers.
TESTING THE RF TRANSMISSION
It is important to site the Receiver and Control Centre in
locations where the RF signal cannot be interrupted. The
receiving range between Control Centre and Receiver is
60M in open area. Many factors can affect the RF
transmission, shortening the operating distance e.g.
shielding by thick walls, foil back plasterboard, metal
objects such as filing cabinets, general RF interference
etc, However, the range is enough for most household
applications.
It is advisable to test the RF transmission from the
intended Control Centre location to the Receiver location
before fixing the Control Centre to the wall.
1. Press UP button until the set-point temperature is higher
than room temperature by a few degrees.
2. Wait for a few seconds. The animated flame (heat call
indicator) should appear on the bottom left of the LCD on
the control centre.
3. Check the green LED on the receiver unit. It should be
illuminated.
4. Press Down button to adjust the set-point temperature to
be lower than room temperature. Wait for a few seconds.
The animated flame (heat call indicator) should disappear
and the green LED should switch off
5. If at step 3 the LED is not illuminated, press RESET and try
to place the Control Centre closer to the Receiver,
repeating steps 1 to 4.
6. Alternatively you can try and alter the address code
following the 'RF Address Code Setting' section of this
manual, then repeat steps 1 to 4.
Note that the RESET button on the Control Centre should be
pressed after altering the address code.
Following table is the setting of the
thermostat after reset or Power on:
Function
Operation Mode
Room Temperature
°C indicator
Clock
AM/PM indicator
Day of Week indicator M
Program
Setpoint Temperature Default factory sett
Program Number
indicator
SET indicator
PROG indicator
Frost Protection
indicator
Heat indicator
Low-Battery Warning
indicator
Output Relay
After reset or power on, the thermostat will o
Normal mode. Setpoint temperature is reset t
setting. Room temperature is updated in 5 se
the control process starts. Program Number is
to indicate the running program.
6
7
Status after Reset or
Normal mode
22.0°C, to be renew
within 5 seconds
On
12:00
AM
Default factory sett
1
Off
Off
Off
Off
Off, to be renewed
within 5 seconds
Off

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents