Table 6. NetWare driver messages for the Ethernet controller (continued)
Message
Error identifying slot numbers for the
specified board names.
Can't unbind specified slot from AFT
group. Make sure that the slot you
specified is for the primary adapter
in an AFT group.
LAN adapter at slot nnnn (Port 0xaa)
failed to reset. Check the state of the
adapter.
AFT is not supported on this version
of NetWare.
Failed to allocate resources tags.
Please unload all LAN drivers before
unloading AFT.NLM.
NDIS 4.0 (Windows NT) driver messages
This section contains the error messages for the NDIS 4.0 drivers. The explanation
and recommended action are included with each message.
Table 7. NDIS (Windows NT) driver messages for the Ethernet controller
Error code (hex)
Description
0x00
Explanation: The driver could not register the specified interrupt. Action:Using the
Configuration/Setup Utility program, make sure that a PCI interrupt is assigned to your
Ethernet card, and that Ethernet is enabled.
0x01
Explanation:One of the PCI cards did not get the required resources. Action:Using the
Configuration/Setup Utility program, make sure that a PCI interrupt is assigned to your
Ethernet card, and that Ethernet is enabled.
0x02
Explanation:Bad node address (multicast address). Action:Make sure the locally administered
address is valid, if one is specified. The address can not be a multicast address.
0x03
Explanation: Failed self-test. Action:Make sure a cable is attached to the Ethernet connector. If
the problem persists, call for service.
0x0D
Explanation: Could not allocate enough memory for transmit queues. Action:
1. From the Windows NT desktop, select Start --> Control Panel --> Networks --> Adapters.
2. Select your IBM Ethernet adapter from the list.
3. Select Properties --> Advanced.
4. Lower the resource values that apply to the transmit queue.
®
®
96
IBM
IntelliStation
E Pro: User's Guide IntelliStation E Pro Types 6836, 6846
Description
Explanation:The mapping between the board name entered and the slot
number for an adapter could not be established. Action:Check the board
name for the adapter before issuing the bind command. If the problem
persists, contact your network supplier.
Explanation:The number entered in the unbind command was not the
primary adapter in an AFT group. Action:Reissue the unbind command and
specify the slot number for the primary adapter.
Explanation: The adapter that you specified could not be initialized. Action:
1. Load the driver for the supported adapter.
2. Check that the adapter is seated properly in the slot and try loading the
AFT module again.
If the problem persists, contact your network supplier.
Explanation:The NetWare on your system is not a version supported by
AFT. Action:Load and bind AFT only on supported versions of NetWare
(currently version 4.11 and above).
Explanation:An unknown error has occurred when trying to allocate needed
resources for the AFT module. Action:Check system configuration. If the
problem persists, contact your network supplier.
Explanation:An attempt was made to unload the AFT.NLM module before
unloading the adapter driver. Action:Unload the adapter driver before
unloading the AFT module.