Specifications; Safety And Compliances - Fluke 187 User Manual

True rms multimeter
Hide thumbs Also See for 187:
Table of Contents

Advertisement

Safety and Compliances

Maximum voltage between any terminal and earth
ground.
Compliances - DUAL RATINGS
Certifications (Iisted and pending)
W
Surge Protection
W
Fuse Protection for mA or A inputs
Fuse Protection for A input
Markings
* OVERVOLTAGE (Installation) Categories refer to the level of Impulse Withstand Voltage protection provided at the specified
Pollution Degree.
Overvoltage Category III equipment is equipment in fixed installations. Examples include switch gear and polyphase motors.
Overvoltage Category IV equipment is equipment for use at the origin of the installation. Examples include electricity meter
and primary over-current protection equipment.
1000 V dc or rms ac
Complies with IEC 1010-1 to 1000 V Overvoltage Category III,
Pollution Degree 2; and IEC 664-1 to 600 V Overvoltage Category
IV, Pollution Degree 2 *
CSA per standard CSA/CAN C22.2 No. 1010.1-92
UL per standard UL 3111 TÜV per standard EN 61010 Part 1-1993
8 kV peak per IEC 1010.1-92
0.44 A (44/100 A, 440 mA), 1000 V FAST Fuse
P
)
11 A, 1000 V FAST Fuse
#
,
,UL, TÜV and
Chapter 7

Specifications

7-1