Fluke 8808A User Manual page 30

Hide thumbs Also See for 8808A:
Table of Contents

Advertisement

8808A
Users Manual
To replace the current-input fuses:
2-6
1. Remove power from the Meter by unplugging its power cord.
2. Turn the Meter upside down.
3. Remove the retaining screw on the fuse access door located on the bottom of the
Meter. See Figure 2-2.
4. Remove the protective cover from the fuse holders by slightly depressing the
back edge of the cover to unlatch it from the printed circuit board. Pull up on the
back edge of the cover and remove it from the fuse compartment.
5. Remove the defective fuse and replace it with a fuse of an appropriate rating. See
Table 2-1.
6. Replace the protective cover by pushing it over the fuses while aligning the
catches with the holes in the printed circuit board. Press the cover down until the
catches engage the printed circuit board.
7. Replace the fuse access door and install the retaining screw.
Fuses
F1
Figure 2-2. Replacing the Current-Input Fuses
F2
Bottom front
left corner
eue04.eps