General Specifications

Maximum Voltage Applied to any Terminal.........1000 V ac rms or dc
Storage Temperature ..........................................-40 C to 60 C (-40 F to 140 F)
Operating Temperature .......................................-20 C to 55 C (-4 F to 131 F)
Temperature Coefficient......................................0.05 x (specified accuracy) per C for temperatures <18 C or >28 C (<64 F or >82 F)
Relative Humidity ................................................Noncondensing
Vibration ..............................................................Random, 2 g, 5-500 Hz per MIL-PRF-28800F, Class 2 instrument
Shock ..................................................................1 meter drop per IEC 61010-1 2
Electromagnetic Compatibility .............................In an RF field of 3 V/M, accuracy = specified accuracy except in temperature: accuracy =
Safety ..................................................................Complies with ANSI/ISA 82.02.01 (61010-1) 2004, CAN/CSA-C22.2 NO. 61010-1-04, and
Certifications........................................................CSA per standard CSA/CAN C22.2 No. 61010.1-04; TUV per standard EN 61010 Part
Batteries ..............................................................Four AA batteries (NEDA 15A or IEC LR6)
Battery Life ..........................................................Meter use 1000 hours; Insulation test use: Meter can perform at least 1000 insulation
Size .....................................................................5.0 cm H x 10.0 cm W x 20.3 cm L
Weight .................................................................550 g (1.2 lb.)
IP Rating..............................................................IP40
Altitude
Operating ........................................................2000 m CAT III 1000 V, CAT IV 600 V; 3000 m CAT II 1000 V, CAT III 600 V
Storage............................................................12,000 m
0 % to 95 % @ 10 C to 30 C (50 F to 86 F)
0 % to 75 % @ 30 C to 40 C (86 F to 104 F)
0 % to 40 % @ 40 C to 55 C (104 F to 131 F)
specified accuracy 5 C (9 F). (EN 61326-1:1997).
nd
IEC/EN 61010-1 2
Edition for measurement category III 1000 V (CAT III) and CAT IV
600 V.
1-1002
tests with fresh alkaline batteries at room temperature. These are standard tests of
1000 V into 1 M
with a duty cycle of 5 seconds on and 25 seconds off.
(1.97 in H x 3.94 in W x 8.00 in L)
nd
Edition (1 meter drop test, six sides, oak floor)