Honeywell WAVE2EX - Ademco Two Tone Siren Installation And Setup Manual page 58

Self-contained, rechargeable wireless control/communicators
Table of Contents

Advertisement

LYNXR-I Installation and Setup Guide
System Communication
Report
Alarm
Trouble
Bypass
AC Loss
Low Battery
Open
Close
Test
Restore Alarm
AC Restore
Low Battery Restore
Trouble Restore
Bypass Restore
ADEMCO Contact ID® Reporting takes the following format: CCCC Q EEE GG ZZZ where:
CCCC = Customer (subscriber) ID
Q
= Event qualifier, where: E = new event, and R = restore
EEE
= Event code (3 hex digits) (for a complete list of event codes, refer to the central office receiver manual)
GG
= Always "00"
ZZZ
= Zone/Contact ID® number reporting the alarm, or user number for open/close reports. System status
messages (AC Loss, Walk Test, etc.) contain zeroes in the ZZZ location.
Code
110
Fire Alarm
121
Duress
122
Alarm, 24-hour Silent
123
Alarm, 24-hour Audible
131
Alarm, Perimeter
132
Alarm, Interior
134
Alarm, Entry/Exit
135
Alarm, Day/Night
146
Silent Burglary
150
Alarm, 24-Hour Auxiliary
301
AC Power
302
Low System Battery/Battery Test Fail
344
RF Jam Detected
353
ECP Communication/Supervision failure, case
tamper or low battery
373
Fire Loop Trouble
374
Exit Error Alarm
380
Global Trouble, Trouble Day/Night
Notes: (1) The following codes are logged in the event log upon occurrence, but are not reported:
305 = System Reset
627 = Keypad Program Mode Entry
(2) LRR/IP Communications Module Low Battery and Low Battery restore reports are sent real time. LRR/IP Communications
Module trouble restore report is sent after two code + off (only if physically restored)
3+1/4+1 Standard
SSS(S) A
SSS(S) T
SSS(S) B
SSS(S) E
SSS(S) L
SSS(S) O
SSS(S) C
SSS(S) G
SSS(S) R
SSS(S) R A
SSS(S) R L
SSS(S) R T
SSS(S) R B
CONTACT ID® EVENT CODES
Definition
3+1/4+1 Expanded
SSS(S) A
AAA(A) Z
SSS(S) T
TTT(T) t
SSS(S) B
BBB(B) b
SSS(S) E
EEE(E) A C
SSS(S) L
LLL(L) L B
SSS(S) O
OOO(O) U
SSS(S) C
CCC® U
SSS(S) G
GGG(G)g
SSS(S) R
RRR® Z
SSS(S) R A
R A R A R A (R A )A c
SSS(S) R L
R L R L R L (R L )L B
SSS(S) R T
R T R T R T (R T )t
SSS(S) R B
R B R B R B (R B )b
Code
381
RF Supervision Trouble
383
RF Sensor Tamper
384
RF Sensor Low Battery
401
Disarmed, Armed AWAY (NO DELAY),
Armed AWAY
403
Scheduled Auto Arm
406
Cancel by User
407
Remote Arm/Disarm (Downloading)
408
Quick Arm AWAY/NO DELAY
441
Disarmed/Armed STAY/NO DELAY, Quick Arm
STAY/NO DELAY
570
Bypass
602
Periodic Test
606
AAV to follow
607
System Test
623
Event Log 80% Full
654
System Inactivity
- 58 -
4+2
SSSS AZ
SSSS Tt
SSSS Bb
SSSS EA C
SSSS LL B
SSSS OU
SSSS CU
SSSS Gg
SSSS RZ
SSSSR A A c
SSSS R L L B
SSSS R T t
SSSS R B b
Definition
(Trouble)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ademco lynxr-i

Table of Contents