ARMING YOUR SYSTEM IN THE "AWAY" MODE

AWAY is utilized when the user is going away from the premise and wants the
interior protected. Listed below are the steps to arm in the AWAY Mode:
Step 1
Close all protected doors and windows.
Ready light will be on or
flashing when all protected
zones
secure. NOTE: If any zones
are bypassed, a sensor in
that zone can be violated without affecting the ready light.
The security system will not
arm if the ready light is off.
Refer
System Ready to Arm".
If the power light is off, you have no AC power. Restore power if
possible. If not, contact the installing company.
Step 2
Enter your 4 or 6 digit user code to arm the system.
The armed and exit lights will illuminate.
You may now leave the building.
The exit light will flash rapidly for the last 10 seconds of the exit delay as a
warning to the user that the exit time is about to expire. The user may wish
to disarm and rearm the system if more time is needed.

MAKING YOUR SYSTEM READY TO ARM

If the ready light is not on or if it is flashing, a zone is not secure. To identify this
zone, use the scroll keys • – to the right of the display to browse through the
zones that are not normal. If you wish to bypass or unbypass one of these zones,
press the [BYPASS] key while that zone is being displayed. When finished
viewing the zones, press the #
NX148E-CF

KEYPAD FUNCTIONS

and
sensors
to
"Making
Your
IMPORTANT!
key to return to the code entry screen.
System Ready
are
Type Code to Arm
System Not Ready
For help, press º
System Armed
All Zones Secure
7