Laser Power Check - Sony MZ-R70 Service Manual

Service manual
Hide thumbs Also See for MZ-R70:
Table of Contents

Advertisement

• Overall MO adjustment items
Item No.
112
113
MO electrical offset adjustment
114
118
221
Low reflective CD TE gain adjustment
223
Low reflective CD TE offset adjustment
232
236
Low reflective CD ABCD level adjustment
244
Low reflective CD focus gain adjustment
245
Low reflective CD tracking gain adjustment
121
MO TE gain adjustment
122
MO TE offset adjustment
134
MO TWPP gain adjustment
131
MO x2 speed read TWPP offset adjustment
132
136
MO ABCD level adjustment
144
MO focus gain adjustment
145
MO tracking gain adjustment
434
MO write TWPP gain adjustment
431
MO write TWPP offset adjustment
432
436
MO write ABCD level adjustment
445
MO write tracking gain adjustment
411
MO x1 speed read TWPP offset adjustment
412
448
32 cluster full recording
141
MO focus bias adjustment
13. To clear the data in overall adjustment mode, set the manual
mode and change the mode number 021 (Res NV) to reset the
NV. (See page 14)
14. When both CD and MO overall adjustments are OK, set the
manual mode and clear the clock data.
For the microprocessor version 1.20 or later, set the mode num-
ber 043 (Resume).
Note: In the mode number 043 (Resume), "Res
be seen because of too fast processing.
If microprocessor version 1.20 or later
LCD display
r Press the X key, historical data clear
Note: In step 10, set the clock data to 99Y11M11D11H11M00S,
and in step 14, do not set the clock.
Contents
" display cannot
– 23 –

5-8. LASER POWER CHECK

Connection :
Optical pick-up
objective lens
MAIN board
Between TP1001
and TP1002
Check Method :
1. Select the manual mode of test mode, and set the laser power
adjusting mode. (mode number 010)
2. Press the
key continuously until the optical pick-up
.
moves to the most inward track.
3. Open the cover and set the laser power meter on the objective
lens of the optical pick-up.
4. Press the
key, and set the laser MO read adjustment mode.
N
(mode number 011)
5. Check that the laser power meter reading is 0.81 ± 0.08 mW.
6. Check that the voltage between TP1001 and TP1002 at this
time is below 44 mV.
7. Press the
N
key, and set the laser CD read adjustment
mode. (mode number 012)
8. Check that the laser power meter reading is 0.97 ± 0.10 mW.
9. Check that the voltage between TP1001 and TP1002 at this
time is below 44 mV.
10. Press the
key, and set the laser MO write adjustment mode.
N
(mode number 013)
11. Check that the laser power meter reading is 4.95 ± 0.50 mW.
12. Check that the voltage between TP1001 and TP1002 at this
time is below 80 mV.
13. Press the
key.
x
14. Release the test mode.
laser
power meter
digital voltmeter