3.
Disconnect the AC power cord 2 from the supply.
Figure 67 Disconnecting AC power
0.7.01.18 UNRECOVERABLE condition—EMU hardware failure
The EMU has detected an internal hardware problem. This condition report remains active until the
problem is corrected.
Complete the following procedure to correct this problem:
1.
Record all six characters of the condition report.
2.
Reset the EMU.
3.
Observe the EMU to ensure the error does not recur within the first minute.
4.
If the error does recur, contact your HP authorized service representative. The EMU is inoperative
and must be replaced as soon as possible.
0.7.01.19 UNRECOVERABLE condition—EMU ESI driver failure
The EMU has detected an internal hardware problem. This condition report remains active until the
problem is corrected.
Complete the following procedure to correct this problem:
1.
Record all six characters of the condition report.
2.
Reset the EMU.
3.
Observe the EMU to ensure the error does not recur within the first minute.
4.
If the error does recur, contact your HP authorized service representative. The EMU is inoperative
and must be replaced as soon as possible.

Transceiver conditions

The format of a transceiver condition report is 0.F.en.ec, where:
0.F. is the transceiver element type number
en. is the two-character transceiver element number (see
1
2
3
HP StorageWorks 4x00/6x00/8x00 Enterprise Virtual Array user guide
4
CXO7490A
Figure
68)
159