Localized High Temperature Zones; Thermal Considerations For Components - Intel D845PEBT2 Specification

Desktop board
Hide thumbs Also See for D845PEBT2:
Table of Contents

Advertisement

Intel Desktop Board D845PEBT2 Technical Product Specification
Figure 23 shows the locations of the localized high temperature zones.
Table 58 provides maximum case temperatures for components on the Desktop Board
D845PEBT2 that are sensitive to thermal changes. The operating temperature, current load, or
operating frequency could affect case temperatures. Maximum case temperatures are important
when considering proper airflow to cool the Desktop Board D845PEBT2.
Table 58.

Thermal Considerations for Components

Component
Intel Pentium 4 processor
Intel 82845PE MCH
Intel 82801DB ICH4
For information about
Intel Pentium 4 processor datasheets and specification updates
84
D
A
Processor voltage regulator area
B
Processor
C
Intel 82845PE MCH
D
Intel 82801DB ICH4
Figure 23. Localized High Temperature Zones
Maximum Case Temperature
For processor case temperature, see processor datasheets and
processor specification updates
o
83
C (under bias)
o
110
C (under bias)
A
B
C
OM15050
Refer to
Section 1.2, page 16