Cf_Corner-Ur Command; Cf_Corner-Dl Command; Cf_Corner-Dr Command - Sanyo PLC-XU116 - 4500 Lumens Manual

Expand serial command functional specifications
Hide thumbs Also See for PLC-XU116 - 4500 Lumens:
Table of Contents

Advertisement

PLC-XU116 Expand Serial Command Functional Specifications
8.7.6

CF_CORNER-UR Command

Command
"CF_CORNER-UR_%1"[CR]
"UP" ------------ Correct the horizontal line of image upwards
"DN" ------------ Correct the horizontal line of image downwards
%1
"LEFT" --------- Correct the vertical line of image to the left
"RIGHT" ------- Correct the vertical line of image to the right
Correct the top-right corner of the image. (Available in normal Power ON status
only)
The correction starts with the first command received
Details
Projector returns error code ""101 and no operation is made when exceeding the
correction limit,
Acceptable
Response
Unacceptable
8.7.7

CF_CORNER-DL Command

Command
"CF_CORNER-DL%1"[CR]
"UP" ------------ Correct the horizontal line of image upwards
"DN" ------------ Correct the horizontal line of image downwards
%1
"LEFT" --------- Correct the vertical line of image to the left
"RIGHT" ------- Correct the vertical line of image to the right
Correct the bottom-left corner of the image. (Available in normal Power ON status
only)
The correction starts with the first command received
Details
Projector returns error code ""101 and no operation is made when exceeding the
correction limit,
Acceptable
Response
Unacceptable
8.7.8

CF_CORNER-DR Command

Command
"CF_CORNER-DR_%1"[CR]
"UP" ------------ Correct the horizontal line of image upwards
"DN" ------------ Correct the horizontal line of image downwards
%1
"LEFT" --------- Correct the vertical line of image to the left
"RIGHT" ------- Correct the vertical line of image to the right
Correct the bottom-right corner of the image. (Available in normal Power ON
status only)
The correction starts with the first command received
Details
Projector returns error code ""101 and no operation is made when exceeding the
correction limit,
Acceptable
Response
Unacceptable
"000"[CR]
"Error Code"[CR]
"000"[CR]
"Error Code"[CR]
"000"[CR]
"Error Code"[CR]
31/72