PLC-XU116 Expand Serial Command Functional Specifications
8.4.5

CF_SHARP Command

Command
"CF_SHARP_%1"[CR]
"000~015" ---------------- Directly select Sharpness setting value
%1
"UP" ------------------------ Current Sharpness setting value + 1
"DN" ------------------------ Current Sharpness setting value - 1
Set Sharpness value of user control
The value set by this command will not be saved to projector. Therefore, when
Details
turning into Stanby status or ALL is OFF, the value returns to original setting. (The
value is held in Suspend mode.)
This command is available in normal Power ON status.
Acceptable
Response
Unacceptable
8.4.6

CF_GAMMA Command

Command
"CF_GAMMA_%1"[CR]
"000~015" ---------------- Directly set Gamma setting value
%1
"UP" ------------------------ Current Gamma setting value + 1
"DN" ------------------------ Current Gamma setting value – 1
Set Gamma value of user control
The value set by this command will not be saved to projector. Therefore, when
Details
turning into Stanby status or ALL is OFF, the value returns to original setting. (The
value is held in Suspend mode.)
This command is available in normal Power ON status.
Acceptable
Response
Unacceptable
8.4.7

CF_WBAL - Command

Command
"CF_WBAL-%1_%2"[CR]
"ÿ 2 " --------------------- Red
%1
"ÿ ' " --------------------- Green
"ÿ " " --------------------- Blue
"000~063" ----------- Directly select Color value specified by White Balance%1
%2
"UP" ------------------- Current Color value set by White Balance%1 + 1
"DN" ------------------- Current Color value set by White Balance%1 - 1
Set Color value set by White Balance%1 of user control
The value set by this command will not be saved to projector. Therefore, when
Details
turning into Stanby status or ALL is OFF, the value returns to original setting. (The
value is held in Suspend mode.)
This command is available in normal Power ON status.
Acceptable
Response
Unacceptable
"000"[CR]
"Error Code"[CR]
"000"[CR]
"Error Code"[CR]
"000"[CR]
"Error Code"[CR]