PLC-ZM5000/ZM5000L Expand Serial Command Functional Specifications
8.7.10 CF_CORNER-UR Command
Command
"CF_CORNER-UR_%1"[CR]
"UP" ------------ Correct the horizontal line of image upwards
"DN" ------------ Correct the horizontal line of image downwards
%1
"LEFT" --------- Correct the vertical line of image to the left
"RIGHT" ------- Correct the vertical line of image to the right
Correct the top-right corner of the image.
(Available in normal Power ON status only)
The correction starts with the first command received
Details
Projector returns error code ""101 and no operation is made when exceeding
the correction limit,
Acceptable
Response
Unacceptable
8.7.11 CF_CORNER-DL Command
Command
"CF_CORNER-DL%1"[CR]
"UP" ------------ Correct the horizontal line of image upwards
"DN" ------------ Correct the horizontal line of image downwards
%1
"LEFT" --------- Correct the vertical line of image to the left
"RIGHT" ------- Correct the vertical line of image to the right
Correct the bottom-left corner of the image.
(Available in normal Power ON status only)
The correction starts with the first command received
Details
Projector returns error code ""101 and no operation is made when exceeding
the correction limit,
Acceptable
Response
Unacceptable
8.7.12 CF_CORNER-DR Command
Command
"CF_CORNER-DR_%1"[CR]
"UP" ------------ Correct the horizontal line of image upwards
"DN" ------------ Correct the horizontal line of image downwards
%1
"LEFT" --------- Correct the vertical line of image to the left
"RIGHT" ------- Correct the vertical line of image to the right
Correct the bottom-right corner of the image.
(Available in normal Power ON status only)
The correction starts with the first command received
Details
Projector returns error code ""101 and no operation is made when exceeding
the correction limit,
Acceptable
Response
Unacceptable
"000"[CR]
"Error Code"[CR]
"000"[CR]
"Error Code"[CR]
"000"[CR]
"Error Code"[CR]
36/89