Create a new nPartition

Creating a new nPartition involves specifying one or more cells in a server complex, setting
various attributes for the cells, and optionally specifying other nPartition settings. The settings
you specify then are used to create a new nPartition, which has assigned to it the cells you selected.
At least one cell in each nPartition must be connected to an I/O chassis that has core I/O attached.
To boot an operating system from disk, the nPartition also must have a boot device and associated
PCI card.
When creating an nPartition, follow the HP nPartition requirements and guidelines. HP
recommends only specific sets of nPartition configurations.
Procedure 4-30 Creating a new nPartition [nPartition commands]
Create a new nPartition using the following procedure:
1.
Log in to Windows on the management station PC. Plan your nPartition configuration by
selecting which cells will compose the new nPartition.
Issue the parstatus -AC command to list all unassigned (available) cells in the server
complex.
NOTE:
commands (-h and -g for IPMI over LAN connections; -h and -u for WBEM/WMI
connections). For a complete explanation of these options, see the command description in
"nPartition Commands Reference" (page
# parstatus -AC
[Cell]
Hardware
Location
========== ============ ======= ======= =================== ======= ==== ===
cab0,cell1 absent
cab0,cell3 absent
cab0,cell4 power on
cab0,cell5 absent
cab0,cell6 power on
cab0,cell7 absent
#
You can select any of the cells listed to create the new nPartition; only the cells that are not
"absent" are present within the server complex.
All cells that you choose must meet the hardware requirements for nPartitions (for example,
they all must have the same firmware revision). The cells also must form an nPartition
configuration that HP recommends. At least one cell must have an I/O chassis with core I/O.
2.
After confirming that cells you have chosen would establish a valid nPartition configuration,
issue the parcreate -c... command to create a new nPartition with the cells.
When using the parcreate command, specify only the -B option if you want the nPartition
to be booted and become active. The -B option causes parcreate to immediately boot the
newly created nPartition past the default shutdown for reconfig state.
By not specifying -B, you can further modify the new nPartition because it remains inactive
at the shutdown for reconfig state (until you boot it using the BO command at the management
processor Command menu).
If you are creating a single-cell nPartition, use just one -c option.
To create a multiple-cell nPartition, specify the -c option multiple times (once for each cell)
issuing a single command line.
You must include the correct remote administration options when issuing nPartition
CPU
OK/
Actual
Failed/ OK/
Usage
Max
-
-
4/0/4
-
4/0/4
-
89).
Memory
(GB)
Failed
Connected To
-
-
-
-
2.0/0.0 cab 0,bay0,chassis3 yes
-
-
2.0/0.0 cab 0,bay1,chassis1 yes
-
-
Use
Core
On
cell
Next Par
Capable Boot Num
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
nPartition-level tasks