Issue commands to list details about system power status.
parstatus -B — Power status summary for all cabinets.
parstatus -V -b# — Detailed power status for the specified cabinet (-b#, where #
is the cabinet number).
frupower -d -C — Cell power status.
frupower -d -I — I/O chassis power status.
NOTE:
commands (-h and -g for IPMI over LAN connections; -h and -u for WBEM/WMI
connections). For a complete explanation of these options, see the command description in
"nPartition Commands Reference" (page

List fan and blower status

Fan and blower status includes lists of cabinet blowers and I/O fans, and their status (whether
ok or failed).
List fan and blower status using the following procedure:
Procedure 4-42 Listing fan and blower status [nPartition commands]
From the command line, issue the parstatus -B command for a fan and blower status summary
for all cabinets, or parstatus -V -b# for detailed fan and blower status for the specified
cabinet (-b#, where # is the cabinet number).
1.
Log in to Windows on the management station PC.
2.
Issue commands to list details about system power status.
parstatus -B — Fan and blower status summary for all cabinets.
parstatus -V -b# — Detailed fan and blower status for the specified cabinet (-b#,
where # is the cabinet number).
NOTE:
commands (-h and -g for IPMI over LAN connections; -h and -u for WBEM/WMI
connections). For a complete explanation of these options, see the command description in
"nPartition Commands Reference" (page

Turn attention indicators (LEDs) on and off

HP's nPartition systems provide attention indicators (LEDs) to help you to visually select and
confirm which hardware you want to perform operations on. Attention indicators are amber
(orange) lights.
Table 4-1
lists the meanings for the various attention indicator states. When all components of a
system are functioning and no service operations are occurring, every attention indicator should
be turned off. (HP Superdome cabinet number LCDs remain lit or blinking when cabinet power
is on.)
Table 4-1 Attention indicator (LED) states and meanings
Attention Indicator State
OFF
BLINKING
ON
80
Using Other Tools to Manage nPartitions
You must include the correct remote administration options when issuing par
You must include the correct remote administration options when issuing par
Meaning
Not selected.
Selected to be used in a service operation.
Supported for PCI card slot LEDs only.
Service required, problems have been identified with the component.