Command Table

(1) Operation Control
Item
Monitor Select
VCR/Camera Select
Still ON/OFF
Multiscreen Select
Sequence
Sequence Mode
Select
Electronic Zoom
ON/OFF
Single Spot CH Select
Camera & Playback Display
Playback CH Select
Alarm Input
Alarm Reset
Alarm Log Clear
Note: If a command has no parameter value, it is processed with the value under lined in the table.
(2) Mode Change
Item
Alarm Suspension
Lock *1
Setup
*1: The LOCK (key lock) command is used to prohibit operations on the panel of the Video Multiplexers and the System
Controllers. After execution of this command, only the personal computer can operate the system.
79
Transmission
Command (ASCII)
OMS : m
OVC : m
OST : m : nn
OTC : m
OSQ : m
OSE : m
OZM : m
OCS : mm
OVS : mm
OAI : m
OAL : m
OAR
Transmission
Command (ASCII)
MAD : m
MKL : m
MSU : m
Response
Command (ASCII)
m=0
OMS
m=1
m=2
m=0
OVC
m=1
m=0
m=1
OST
nn=00 All video channels specify
nn=01 - 16 Camera Number
m=0
m=2
OTC
m=4
m=1
m=0
OSQ
m=1
m=0
OSE
m=1
m=2
m=0
OZM
m=1
mm=00 - 16 Camera Number
OCS
*00=Spot Input
OVS
mm=01 - 16 Playback CH number
m=0
OAI
m=F
m=0
OAL
m=1
OAR
None
Response
Command (ASCII)
m=0
MAD
m=1
m=0
MKL
m=1
m=0
MSU
m=1
Parameter (ASCII)
Spot Monitor
Multiscreen Monitor
Multiscreen 2 Monitor
Camera Mode
VCR Mode
Still OFF
Still ON
Quad
m=1
7 divide
9 divide
m=3
10 divide
13 divide m=5 16 divide
No. of divisions (+) m=D No. of divisions ( )
End Sequence
Activate Sequence
SEQ1
SEQ2
SEQ3
Zoom OFF
Zoom ON
1CH Alarm
:
16CH Alarm
Manual Reset
Auto Reset
Parameter (ASCII)
Alarm Suspension OFF
Alarm Suspension ON
Lock OFF
Lock ON
End Setup
Begin Setup

Advertisement

Table of Contents
loading