HP StorageWorks 8/20q User Manual page 132

Hp storageworks 8/20q and sn6000 fibre channel switch enterprise fabric management suite user guide (5697-0420, june 2010)
Hide thumbs Also See for StorageWorks 8/20q:
Table of Contents

Advertisement

Table 30
Port Statistics data window fields (continued)
Field
BB_CreditRecoveryFrameFailure
BB_CreditRecoveryRRDYFailure
Class 2 Frames In
Class 2 Frames Out
Class 2 Words In
Class 2 Words Out
Class 3 Frames In
Class 3 Frames Out
Class 3 Toss
Class 3 Words In
Class 3 Words Out
Decode Errors
Ep Connects
FBusy
Flow Errors
FReject
Invalid CRC
Invalid Destination Address
Link Failures
LIP(AL_PD,AL_PS)
LIP(F7,AL_PS)
132 Managing Ports
Description
Number of times more frames were lost during a credit recovery
period than the recovery process could resolve. This generates a Link
Reset to recover the credits.
Number of times more R_RDYs were lost during a credit recovery
period than the recovery process could resolve. This generates a Link
Reset to recover the credits.
Number of class 2 frames received by this port
Number of class 2 frames transmitted by this port
Number of class 2 words received by this port
Number of class 2 words transmitted by this port
Number of class 3 frames received by this port
Number of class 3 frames transmitted by this port
Number of class 3 frames that were discarded by this port. A frame
may be discarded because a missing frame or an E_D_TOV timeout
is detected, a reject frame is received, or a frame is received on an
offline port.
Number of class 3 words received by this port
Number of class 3 words transmitted by this port
Number of invalid words transmitted detected during decoding.
Decoding is from the 10-bit characters and special K characters.
Number of E_Port logins
Number of class 2 and class 3 fabric busy (F_BSY) frames generated
by this port in response to incoming frames. This usually indicates a
busy condition on the fabric or the N_Port that is preventing delivery
of this frame.
Number of times a frame is received when all the switch ports receive
buffers are full. The normal Fabric Login exchange of flow control
credit should prevent this from occurring. The frame is discarded.
Number of frames, from devices, that have been rejected. Frames can
be rejected for many reasons.
Number of invalid Cyclic Redundancy Check (CRC) frames detected
Number of address identifier (S_ID, D_ID) errors. AL_PA equals
non-zero AL_PA found on F_Port.
Number of optical link failures detected by this port. A link failure is a
loss of synchronization or by loss of signal while not in the offline
state. A loss of signal causes the switch to attempt to re-establish the
link. If the link is not re-established, a link failure is counted. A link
reset is performed after a link failure.
Number of F7, AL_PS LIPs, or AL_PD (vendor specific) resets
performed
Used to reinitialize the loop. An L_port, identified by AL_PS, may
have noticed a performance degradation and is trying to restore the
loop.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sn6000

Table of Contents