For All Combis - Convotherm OGB-10.10 Installation And Maintenance Instructions Manual

Combination oven steamer
Hide thumbs Also See for OGB-10.10:
Table of Contents

Advertisement

9. For ALL Combis

Do not operate, or attempt to operate an out-of-level Combi:
Tipping over and/or other catastrophic failure can result.
Combis must be level front-to-back and side-to-side.
Operating an out-of-level Combi voids the Warranty.
a. Keep the vents on the bottom and top of the Combi clear, clean, and free of obstruction.
b. The floor where the loading trolley rolls must be level and even.
c. Level the floor if needed. (Fig. 7).
d. The trolley must stand level in the Combi.
e. A roll-in ramp, (not provided), may be used. Maximum angle of the roll-in ramp is 4 degrees
(Fig. 8).
f.
If there is a drain grid in front of the Combi, place or affix flat material on the drain grid so
the trolley can roll smoothly over it (Fig. 7).
g. Do not store anything on top of a Combi.
h. Required Clearances: Rear - 2", Left Side - 4". Right Side 2 1/2"
1) Allow for sufficient distance if a "high heat source" (i.e. Broiler) is located next to the
unit
2) Allow for sufficient clearance on left side for service access (contact the factory
service department for recommendations)
3) Installation must comply with all local fire and health codes.
i.
Keep the vents on the top and bottom of the Combi clear, clean, and free of obstruction.
j.
Level the Combi from the bottom: Use the height adjustable legs of the Combi and a level
to so the Combi is level front-to-back and side-to-side (Fig. 6).
10. For Stand Mounted, Stacked, and Caster Equipped Combis
a. Follow the separate instructions included with the Stand, Stacking Kit, or Caster Kit.
b. Use only genuine Convotherm by Cleveland Stacking Kits, Caster Kits, and replacement parts.
c. Use of Stands, Stacking Kits, Caster Kits, and replacement parts other than genuine
Convotherm by Cleveland Stands, Stacking Kits, and Caster Kits can result in injury and / or
catastrophic equipment failure.
d. Use of Stands, Stacking Kits, Caster Kits, and replacement parts other than genuine
Convotherm by Cleveland Stands, Stacking Kits, and Caster Kits will void the Warranty.
WARNING
Out-of-level Combis can TIP OVER!