Configuring Ports And Vlans On Switch 1 (Cli Example) - HP 438031-B21 - 1:10Gb Ethernet BL-c Switch Application Manual

Hp 1:10gb ethernet bl-c switch for c-class bladesystem application guide
Hide thumbs Also See for 438031-B21 - 1:10Gb Ethernet BL-c Switch:
Table of Contents

Advertisement

Configuring ports and VLANs on Switch 1 (CLI example)

To configure ports and VLANs on Switch 1, do the following:
1.
On Switch 1, enable VLAN tagging on the necessary ports.
Main# /cfg/port 1
>> Port 1# tag e
Current VLAN tag support: disabled
New VLAN tag support:
Port 1 changed to tagged.
Main# /cfg/port 17
>> Port 17# tag e
Current VLAN tag support: disabled
New VLAN tag support:
Port 17 changed to tagged.
Main# /cfg/port 19
>> Port 19# tag e
Current VLAN tag support: disabled
New VLAN tag support:
Port 19 changed to tagged.
>> Port 19# apply
2.
Configure the VLANs and their member ports. Since all ports are by default configured for VLAN 1,
configure only those ports that belong to VLAN 2. Crosslink port 17 must belong to VLANs 1 and 2.
>> /cfg/l2/vlan 2
>> VLAN 2# add 1
Current ports for VLAN 2: empty
Pending new ports for VLAN 2: 1
>> VLAN 2# add 19
Current ports for VLAN 2: 1
Pending new ports for VLAN 2: 19
>> VLAN 2# add 21
Port 21 is an UNTAGGED port and its current PVID is 1.
Confirm changing PVID from 1 to 2 [y/n]: y
Current ports for VLAN 2: 1, 19
Pending new ports for VLAN 2: 21
>> /cfg/l2/vlan 3
>> VLAN 3# add 17
Current ports for VLAN 3: empty
Pending new ports for VLAN 3: 17
>> VLAN 3# add 19
Current ports for VLAN 3: 17
Pending new ports for VLAN 3: 19
>> apply
>> save
(Select port 1: connection to server 1)
enabled
(Enable tagging)
(Select crosslink link port 17)
(Enable tagging)
enabled
(Select uplink port 19)
(Enable tagging)
enabled
(Apply the port configurations)
(Add port 1 to VLAN 2)
(Add port 19 to VLAN 2)
(Add port 21 to VLAN 2)
(Add port 17 to VLAN 3)
(Add port 19 to VLAN 3)
(Apply the port configurations)
(Save the port configurations)
VLANs
60

Advertisement

Table of Contents
loading

This manual is also suitable for:

1:10gbe

Table of Contents