HP 438031-B21 - 1:10Gb Ethernet BL-c Switch Application Manual page 158

Hp 1:10gb ethernet bl-c switch for c-class bladesystem application guide
Hide thumbs Also See for 438031-B21 - 1:10Gb Ethernet BL-c Switch:
Table of Contents

Advertisement

258 = port 2
280 = port 24
This value represents the alarm's MIB OID, as a string. Note that for non-tables, you must supply a .0 to
specify end node.
Configure RMON Alarms (CLI example 1)
1.
Configure the RMON Alarm parameters to track the number of packets received on a port.
>> /cfg/rmon/alarm 6
>> RMON Alarm 6# oid 1.3.6.1.2.1.2.2.1.10.276
>> RMON Alarm 6# intrval 3600
>> RMON Alarm 6# almtype rising
>> RMON Alarm 6# rlimit 2000000000
>> RMON Alarm 6# revtidx 6
>> RMON Alarm 6# sample abs
>> RMON Alarm 6# owner "Alarm_for_ifInOctets"
2.
Apply and save the configuration.
>> RMON Alarm 6# apply
>> RMON Alarm 6# save
This configuration creates an RMON alarm that checks ifInOctets on port 20 once every hour. If the
statistic exceeds two billion, an alarm is generated that triggers event index 6.
Configure RMON Alarms (CLI example 2)
1.
Configure the RMON Alarm parameters to track ICMP messages.
>> /cfg/rmon/alarm 5
>> RMON Alarm 5# oid 1.3.6.1.2.1.5.8.0
>> RMON Alarm 5# intrval 60
>> RMON Alarm 5# almtype rising
>> RMON Alarm 5# rlimit 200
>> RMON Alarm 5# revtidx 5
>> RMON Alarm 5# sample delta
>> RMON Alarm 5# owner "Alarm_for_icmpInEchos"
2.
Apply and save the configuration.
>> RMON Alarm 5# apply
>> RMON Alarm 5# save
This configuration creates an RMON alarm that checks icmpInEchos on the switch once every minute. If
the statistic exceeds 200 within a 60 second interval, an alarm is generated that triggers event index 5.
(Select RMON Alarm 6)
(Make your changes active)
(Save for restore after reboot)
(Select RMON Alarm 5)
(Make your changes active)
(Save for restore after reboot)
Remote monitoring
158

Advertisement

Table of Contents
loading

This manual is also suitable for:

1:10gbe

Table of Contents