HP 438031-B21 - 1:10Gb Ethernet BL-c Switch Application Manual page 156

Hp 1:10gb ethernet bl-c switch for c-class bladesystem application guide
Hide thumbs Also See for 438031-B21 - 1:10Gb Ethernet BL-c Switch:
Table of Contents

Advertisement

Configure RMON History (CLI example)
1.
Enable RMON on each port where you wish to collect RMON History.
>> /cfg/port 23/rmon
>> Port 23# ena
>> Port 23 RMON# apply
>> Port 23 RMON# save
2.
Configure the RMON History parameters.
>> /cfg/rmon/hist 1
>> RMON History 1# ifoid 1.3.6.1.2.1.2.2.1.1.23
>> RMON History 1# rbnum 30
>> RMON History 1# intrval 120
>> RMON History 1# owner "Owner_History_1"
3.
Apply and save the configuration.
>> RMON History 1# apply
>> RMON History 1# save
This configuration creates an RMON History group to monitor port 23. It takes a data sample every two
minutes, and places the data into one of the 30 requested buckets. After 30 samples are gathered, the
new samples overwrite the previous samples, beginning with the first bucket. Use SNMP to view the data.
Configure RMON History (BBI example)
1.
Configure an RMON History group.
Click the Configure context button.
a.
Open the Switch folder, and select RMON > History > Add History Group.
b.
(Select Port 23 RMON)
(Enable RMON)
(Make your changes active)
(Save for restore after reboot)
(Select RMON History 1)
(Make your changes active)
(Save for restore after reboot)
Remote monitoring
156

Advertisement

Table of Contents
loading

This manual is also suitable for:

1:10gbe

Table of Contents