In this example, NIC 1 is the primary network adapter; NIC 2, NIC 3, and NIC 4 are non-primary
adapters. NIC 1 and NIC 2 are connected to port 1 and port 2 on Blade Switch 1. NIC 3 and NIC 4 are
connected to port 1 and port 2 on Blade Switch 2.

Configuring UFD on Switch 1 (CLI example)

1.
Assign uplink ports (19-25) to be monitored for communication failure.
>> Main# /cfg/ufd/fdp ena
>> FDP# ltm
>> Failure Link to Monitor# addport 21 (Monitor uplink port 21)
2.
Assign downlink ports (1-16) to disable when an uplink failure occurs.
>> /cfg/ufd/fdp/ltd
>> Failure Link to Disable# addport 1
>> Failure Link to Disable# addport 2
3.
Turn UFD on.
>> /cfg/ufd/on
>> Uplink Failure Detection# apply
>> Uplink Failure Detection# save
When a link failure or Spanning Tree blocking occurs on port 21, Blade Switch 1 disables port 1 and
port 2.

Configuring UFD on Switch 2 (CLI example)

1.
Create a trunk group of uplink ports (19-25) to monitor. First you must set each port to full duplex
mode.
>> Main# /cfg/port 22/gig/mode full
>> Main# /cfg/port 23/gig/mode full
>> Main# /cfg/trunk 2
>> Trunk group 2# ena
>> Trunk group 2# add 22
>> Trunk group 2# add 23
2.
Assign the trunk group to be monitored for communication failure.
>> Main# /cfg/ufd/fdp ena
>> FDP# ltm
>> Failover Link to Monitor# addtrnk 2
3.
Assign downlink ports (1-16) to disable when an uplink failure occurs.
>> Main# /cfg/ufd/fdp/ltd
>> Failover Link to Disable# addport 1
>> Failover Link to Disable# addport 2
4.
Turn UFD on.
>> Main# /cfg/ufd/on
>> Uplink Failure Detection# apply (Make your changes active)
>> Uplink Failure Detection# save
When a link failure or Spanning Tree blocking occurs on trunk group 2, Blade Switch 2 disables port 1
and port 2.
(Enable Failure Detection Pair)
(Select Link to Monitor menu)
(Select Link to Disable menu)
(Add port 1 as a Link to Disable)
(Add port 2 as a Link to Disable)
(Turn Uplink Failure Detection on)
(Make your changes active)
(Save for restore after reboot)
(Set port 22 to full duplex)
(Set port 23 to full duplex)
(Create trunk group 2)
(Enable trunk group 2)
(Add port 22 to trunk group 2)
(Add port 23 to trunk group 2)
(Enable Failover Pair)
(Select Link to Monitor menu)
(Monitor trunk group 2)
(Select Link to Disable menu)
(Add port 1 as a Link to Disable)
(Add port 2 as a Link to Disable)
(Turn Uplink Failure Detection on)
(Save for restore after reboot)
High availability
167

Advertisement

Table of Contents
loading

This manual is also suitable for:

1:10gbe

Table of Contents