Main Assembly 8 (Case Unit); Interface Circuit Board Ass'y And Connector Plate - Epson TM U200D - B/W Dot-matrix Printer Technical Manual

Technical reference
Table of Contents

Advertisement

Main Assembly 8 (Case Unit)

Interface circuit board ass'y and Connector plate

1. Turn over the printer.
2. Attach the Connector plate to the Interface circuit board ass'y and secure with the Hexagon lock
screws (Serial interface) or the CPS-tite screws (parallel interface).
3. Connect the Interface circuit board ass'y to the Main circuit board ass'y and secure with the screws
Serial Interface.
Main circuit board ass'y
Rev.B
CP(0) (M3x6)
[0.59 to 0.78 N • m
(6 to 8 kgf • cm)]
Connector plate
TM-U200D/U200PD Technical Manual
Hexagon
lock screws
[0.39 to 0.59 N • m
(4 to 6 kgf • cm)]
CP(0) (M3x6)
[0.59 to 0.78 N • m
(6 to 8 kgf • cm)]
Interface circuit
board ass'y
Disassembly, Assembly, and Adjustment 5-37