POST Error Messages (Continued)
Screen Message
2201-MEBx Module did
not checksum correctly
2202-PMM
Deallocation Error
during MEBx cleanup
2203-Setup error
during MEBx execution
2204-Inventory error
during MEBx execution
Service Reference Guide, dc7700
Probable Cause
Memory error during
POST execution of the
Management Engine
(ME) BIOS Extensions
option ROM
Memory error during
POST execution of the
Management Engine
(ME) BIOS Extensions
option ROM
MEBx selection or exit
resulted in a setup failure.
BIOS information passed
to the MEBx resulted in a
failure.
433612-001
POST Error Messages
Recommended Action
1. Reboot the computer.
2. Unplug the power cord, re-seat the
memory modules, and reboot the
computer.
3. If the memory configuration was
recently changed, unplug the power
cord, restore the original memory
configuration, and reboot the
computer.
4. If the error persists, replace the
system board.
1. Reboot the computer.
2. Unplug the power cord, re-seat the
memory modules, and reboot the
computer.
3. If the memory configuration was
recently changed, unplug the power
cord, restore the original memory
configuration, and reboot the
computer.
4. If the error persists, replace the
system board.
1. Reboot the computer.
2. Unplug the power cord, re-seat the
memory modules, and reboot the
computer.
3. If the memory configuration was
recently changed, unplug the power
cord, restore the original memory
configuration, and reboot the
computer.
4. If the error persists, replace the
system board.
1. Reboot the computer.
2. If the error persists, update to the
latest BIOS version.
3. If the error still persists, replace the
system board.
C–7