Depending on the depth of the rack used, it may be necessary to remove the server's bezel in order
to close the door of the rack. A minimum of 58 mm will be needed between the back surface of the
door panel and the front face of the EIA flange for the front door to close with the 11G server bezel
installed.

Figure 26. 1U Threaded Rack Adapter Brackets Kit

The static rails support a wider variety of racks than the sliding rails but do not support
serviceability in the rack and are thus not compatible with the CMA.

Figure 27. R410 Static Rails

One key factor in selecting the proper rails is identifying the type of rack in which they will be
installed. Both the sliding rails and the static rails support mounting in 19‖-wide, EIA-310-E
compliant 4-post racks, but only the static rails, as the more generic or ―universal‖ solution, support
mounting in 2-post (Telco) racks.
PowerEdge R410 Technical Guide
44