Environmental Specifications; Power Supply Connector (8 Pins) Signals; Operating/Non-Operating Storage Requirements - Dell External OEMR R410 Technical Manual

Technical guide
Hide thumbs Also See for External OEMR R410:
Table of Contents

Advertisement

Dell

4.3 Environmental Specifications

Table 7.
Temperature Ranges
(For Altitude ≤900 m or 2952.75 ft)
Temperature Ranges
(For Altitude > 900 m or 2952.75 ft)
Temperature Gradient
Maximum per 60 Min.
Humidity Percent Ranges
Non-condensing
Humidity Gradient
Maximum per 60 Min.
Altitude Ranges
Use the following formulas to calculate the maximum operating temperature (in °C) for a given
altitude. Use the first formula if the altitude is stated in meters and the second formula if the
altitude is stated in feet.
Use the following formulas to calculate the maximum operating temperature (in °F) for a given
altitude. Use the first formula if the altitude is stated in meters and the second formula if the
altitude is stated in feet.
,
(
PowerEdge R410 Technical Guide

Power Supply Connector (8 pins) Signals

Table 6.
Pin
Signal
1
GND
2
GND
3
GND
4
GND

Operating/Non-Operating Storage Requirements

(*Max Wet bulb temperature= 29 °C)
Low
Limits
High
Limits
(
)
*
+
-
Pin
Signal
5
P12VA
6
P12VA
7
P12VB
8
P12VB
Operating Requirements
10 to 35 °C
(50 to 95 °F)
1
10 to Note
°C
2
(50 to Note
°F)
10
°C
*
20 to 80 %
10 %
-50 feet
(-15.2 meters)
10,000 feet
(3048 meters)
,
)
(
Non-Operating
Requirements
-40 to 65 °C
(-40 to 149 °F)
20
°C
5 to 95 %
+
(
Max Wet bulb
temperature= 38 °C)
10 %
-50 feet
(-15.2 meters)
35,000 feet
(10,668 meters)
(
)
*
+
-
+
)
26

Advertisement

Table of Contents
loading

This manual is also suitable for:

Poweredge r410