Configuring Switch Information
3
Configuring Fabric
Parameters for the
Switch
EFCM Basic User Manual
3-14
12. Click OK to save and activate the changes. The message Your
changes have been successfully activated displays below the
page's heading.
13. If fabric parameters require configuration, go to
Parameters for the Switch
14. If the configuration is complete, set the product online by
selecting the Switch Online check box on the Configure menu.
Perform this procedure to configure the fabric operating parameters,
including resource allocation time out value (R_A_TOV), E_D_TOV,
product priority, and interop mode. The product must be set offline
to configure the parameters.
NOTE: A 12-Port Switch cannot participate in a fabric, unless the Fabric
Capable feature is enabled.
Perform the following procedure to configure fabric parameters:
1. Set the product offline by clearing the Switch Online check box on
the Configure menu.
2. Select Configure > Switch > Fabric Parameters on the navigation
panel. The Fabric Parameters configuration page
displays.
Figure 3-7
Fabric Parameters Page
3. At the R_A_TOV field, type a value between 10 and 1200 tenths of
a second between 1 and 120 seconds. The R_A_TOV value must
be greater than the E_D_TOV value.
on page 3-14.
Configuring Fabric
(Figure
3-7)