Set The Unit Beaconing State; Clear System Error Lights; Perform A System Configuration Reset - McDATA 316095-B21 - StorageWorks Edge Switch 2/24 User Manual

Fw 08.01.00 mcdata efcm basic user manual (620-000240-000, november 2005)
Hide thumbs Also See for 316095-B21 - StorageWorks Edge Switch 2/24:
Table of Contents

Advertisement

Set the Unit
Beaconing State
Clear System Error
Lights
Perform a System
Configuration Reset
If the value in the Current Online State field is Off, you can set the
product online by selecting the Activate button.
Using the Switch maintenance page, you can enable or disable
beaconing on the product. The current state of beaconing for the unit,
which is either on or off, is displayed by a flashing LED. Beaconing is
useful in helping to isolate problems and locate the product,
especially when there are multiple products stacked together, such as
in a rack-mount cabinet.
The status of beaconing is shown in the Unit Beaconing is field. If the
value shown is On, the product's beacon LED is flashing. To disable
beaconing, select the Deactivate button.
If the Unit Beaconing is field value is Off, the LED is not flashing. To
enable beaconing, select the Activate button.
The amber system error light indicator, shown on the Product
Hardware page, simulates the system error light on the actual switch.
When this indicator illuminates, an event has occurred requiring
immediate attention, such as the failure of the system, power
supply/fan, or port. For more information, see
Indicators, page 2-3.
The status of the system error light is shown by the System Error Light
is field. If the status is On, you can clear the system error light by
selecting the Clear button.
ATTENTION! Service personnel may ask you to perform this operation to
resolve system problems. Review this section completely before performing
this operation.
The Reset Configuration button of the Switch Maintenance page
enables you to reset product configuration values. This enables you
to reset all configuration data and nonvolatile settings to the factory
default values including any data that was created from the Configure
menu and associated pages.
For a list of factory default values, refer to the product's installation
and service manual.
Switch Maintenance Tasks
Table 2-1, Status
Performing Product Maintenance
7
7-3

Advertisement

Table of Contents
loading