Remote auxiliary air conditioning and air distribution systems for volvo l-4 chassis

Advertisement

We recommend you install the return air grill under
the bunk in the side panel on the passenger side. This
will make it less likely for the air flow to be blocked by
something in the luggage compartment, and will also
give you easy access to the quick-connect refrigerant
fittings with a wrench.
The supply air will be routed through the Volvo duct-
work, and will also be ducted to one or two additional
discharge grills, depending on the BTU model you are
installing.
IMPORTANT! Refer to the Dometic instal-
lation manual for details on installing and
connecting the CHEB and condensing
unit.

Volvo L-4 Installation Guidelines
Figure 3 - Laying out the CHEB template
Dometic HVAC
Factory HVAC
Figure 4 - Installing the CHEB
1"
5" between bunk wall
and Dometic HVAC
Refrigerant lines
1" between Dometic HVAC
unit and factory HVAC unit