B
Minimizing Bluetooth/ISM Band
Network Activity
The settings described below can help you customize the re-linking behavior of
the cordless linear imaging system to obtain the best compromise between con-
venience and low interference.
Note: ISM band refers to the 2.4 to 2.48 GHz frequency band used by wireless
networks, cordless phones, and Bluetooth.

Auto Reconnect Mode

Auto Reconnect controls whether or not the image scanner automatically
begins the re-link process when a loss of connection is detected. When the
Auto Reconnect On barcode is scanned, the image scanner begins the re-link
process immediately, without user intervention. Default = Auto Reconnect On.
* Auto Reconnect On
The table below shows the results of the Auto Reconnect On and Off settings:
Event
Image scanner out
of range
Base reset
(firmware upgrade
or power cycle)
Image scanner
power down due to
Power Time-Out
Timer setting (see
page
4-4)
Auto Reconnect On
Re-link occurs
automatically. If
maximum number of link
attempts (see
Maximum
Link Attempts
on page
B-2) is unsuccessful,
then the trigger must be
pulled or the image
scanner must be placed
in the base unit to re-
link.
Image scanner behaves
as if out of range.
Trigger must be pulled or the image scanner must be
placed in the base unit to re-link.
(Note: image scanner re-links on power up, but
powers on due to one of the above actions.)
Auto Reconnect Off
Auto Reconnect Off
The trigger must be pulled
to initiate re-linking.
No attempt to re-link
made while base unit is
powered off. Trigger must
be pulled to initiate re-
linking.
B - 1