Secure by aligning
in the base siots_
To reattach
nozzle
guard, rotate/pivot
back into position,
A
To secure nozzle
guard, rotate lock B
counterclockwise to
the locked position,
Slide lock A to the
right to the locked
position
WARNING
Electrical
Shock
and Personal
Injury
Hazard
Disconnect
electrical
supply
before
servicing
or cleaning
the unit. Failure
to do so could
result
in electrical
shock
or
personal
injury
from vacuum
cleaner
suddenly
starting.
,
i
i
TO REMOVE LIGHT BULB
1. Disconnect
power cord from electrical
outlet,
2. Press handle release pedal and lay
vacuum cleaner back,
3. Remove the two
(2) screws from the
lens cover,
4. Lift the lens cover
to remove,
Do not use a bulb rated over 9W
(13V). During extended
use, heat
from
the bulb could overheat
surrounding
plastic
parts.
i
i ,
,11111,111,1
iii
i
5. Pull bulb out of
socket_ Do NOT
twisL Gently push
bulb into socket to
replace.
6. Snap lens cover
back into place and
secure the headlight
lens by replacing
the
two screws,
Note: See separate PARTS
LIST for bulb
number,