PRIMARY FILTER
Check primary
filter frequently
and clean
when dirty.
TO REMOVE
PRIMARY
FILTER
Remove the dust bin assernbly
as outlined
in the DUST BIN CLEANING
section.
Make sure dust bin is free of debris before
removing
lid and filter. Rotate dust bin lid
assembly
counterclockwise
as indicated
on
the lid and lift off.
Turn This Direction
To Open For Emptying
Closed
(For Use)
Open
(For
Emptying)
While holding dust bin lid over a trash con-
tainer grasp primary
filter, rotate counter-
clockwise
and lift off.
Clean primary
filter by gently tapping over a
trash container. Tap on several
sides to
ensure best cleaning.
Remove primary
filter by turning
it counterclock-
wise and pulling
out (See arrows
on bottom of fil-
ter). Rinse with
water only as
needed,
do not
use any deter-
gent or soap.
Dust
Bin
Lid
Allow the filter to dry for 24 hours
before putting
it back into the vacuum.
When cleaning
the filter no longer
restores vacuum
suction to full power you
need to replace the filter.
Note: See PARTS
AND FEATURES
for the filter number.
TO REPLACE
PRIMARY
FILTER
To replace filter, insert it over cleaning
cams as far as it will go. Make sure rubber
seal at top of filter is flush against
filter sup-
porter, then turn filter clockwise
to secure
into place.
Note: Under normal
use and care, your fil-
ter can be expected
to last up to 5 years.
Rubber
Cams
Supporter
Dust Bin
Lid
Re-assemble dust bin lid to dust bin. see To
REPLACE DUST BIN LID.