Note: See "Server" on page 80 to determine which components should be replaced by a field service technician.
Error code/symptom
262 (DRAM parity configuration error)
289 (DIMM has been disabled by user or
the system)
301 (Keyboard or keyboard controller
error)
303 (Keyboard controller error)
602 (Invalid diskette boot record)
604 (Diskette drive error)
662 (Diskette drive configuration error)
962 (Parallel port configuration error)
11XX (Serial port configuration error)
1301(LED panel cable disconnected)
1600 (The service processor is not
functioning) Complete the following steps
before replacing a FRU:
1. Ensure that a jumper is not installed
on J28.
2. Remove the ac power to the server,
wait 20 seconds; then, reconnect the
ac power. Wait 30 seconds; then, turn
on the server.
1601 (Service processor failed to respond
at the start of POST)
FRU/action
1. Run the Configuration/Setup Utility program.
2. Battery.
3. System board.
1. Run the Configuration/Setup Utility program, if the DIMM was
disabled by the user.
2. Disabled DIMM, if not disabled by user.
3. System board.
1.
Keyboard
2. System board
v System board
1. Diskette
2. Diskette drive
3. Cable
4. System board
1. Run the Configuration/Setup Utility program and diagnostics.
2. Diskette drive.
3. Drive cable.
4. System board.
1. Run the Configuration/Setup Utility program.
2. Diskette drive.
3. Drive cable.
4. System board.
1. Run the Configuration/Setup Utility program.
2. System board.
1. Run the Configuration/Setup Utility program.
2. System board.
1. LED cable assembly.
2. System board.
1. Jumper on J28
2. System board
1. Reset the service processor.
2. Flash the service processor.
3. System board.
Chapter 6. Symptom-to-FRU index