9. Place the adapter, component-side up, on a flat, static-protective surface and
set any jumpers or switches as described by the adapter manufacturer, if
necessary.
Attention:
When you install an adapter in the server, be sure that it is
completely and correctly seated in the PCI expansion slot before you turn on
the server. Incomplete insertion might cause damage to the system board or
the adapter.
PCI-X slot 1
connector
Riser card
PCI-X slot 2
connector
Adapter
10. To install the adapter, carefully grasp the adapter by its top edge or upper
corners, and align it with the PCI-X expansion slot; then, press the adapter
firmly into the expansion slot.
Note: When you install the adapter in PCI-X slot 2, you must slide the adapter
underneath the system fan to properly align the adapter with the
expansion-slot connector. Do not remove the system fan from the
server.
11. If you installed an adapter in PCI-X slot 2, continue with the next step. If you
removed the adapter-support bracket, reinstall it now. Make sure the riser card
is fully seated into the riser card connector on the system board.
12. Tighten the captive screw on the rear of the server.
13. Connect required cables to the adapter.
14. If you have other options to install, do so now; otherwise, go to "Completing
the installation" on page 42.
Adapter-support
bracket
PCI-X riser card
connector
Chapter 4. Customer replaceable units
Adapter
39