15. Push the Jet Pump 3 Button once to turn on pump 3. Let the
system run for 10 to 15 seconds to prime the pump.
16. Then push the Jets Button on the Dynamic Massage Sequencer
to the right of the Top Side Control to start pump 1. Let it run
for 10 to 15 seconds to prime pump 1. Press the button again to
shut the pump off.
17. Then push the Jets Button on the Dynamic Massage Sequencer
to the left of the Top Side Control to start pump 2. Let it run for
10 to 15 seconds to prime pump 2. Press the button again to shut
the pump off.
If there is no jet action, then the water level is too low or there is air
trapped in the plumbing lines. To eliminate the trapped air, turn the
pumps on and off several times to force the trapped air through the
pumps. If there is still no jet action, and the bleeder valves were
removed as previously described, turn off the pumps and loosen the
top pump unions slightly to let any trapped air escape. Re-tighten the
pump unions and turn the pumps on again. Turn the pumps on and off
several times until jets function properly.
Ozone bubbles will continue to release from the skimmer recess Ultra Pure bleeder valve as
long as the valve remains open. Once the pumps are primed, be sure that the bleeder is closed
tightly.
Note
12. When the jets are in full operation, replace and close the bleeder
valves and push the UP/Down Buttons until your desired water
temperature (set temperature) is indicated on the Digital Display
Window. The Digital Display Window will then display your set
temperature for thirty seconds before changing to display the
current water temperature.
While setting the temperature, the Digital Display Window will read out the temperature – up
to 40°C (≅104° F). Water temperatures in excess of 40° C (≅104° F) should be used
with extreme caution.
Warning
Initial start-up, you can confirm that the heater is on by looking to see that the heat LED
indicator located on the right side of the hot tub control panel is illuminated. A scrolling
message will also appear on the lower line of the Digital Display Window reading SPA
HEATING TO _ _ _° C (whatever the set temperature is) as well as an animated icon on the
Digital Display Window. Once you have verified that the heater is functioning, you can reinstall
Note