Troubleshooting
As a last resort, save any RAM objects you've created to disk or SmartMedia, and perform a
hard reset. Do this by pressing the Master-mode button, followed by the MAST2 soft
button, then pressing the Reset soft button (at the lower right of the display). The K2661 will
warn you about deleting everything (only RAM objects will be deleted). Press Yes. After a
few seconds, the power-up display should appear.

Other Possible Problems

No Sound, No Display, No LEDs Illuminated

1. AC line cord not fully inserted into outlet or unit. If using a multiple outlet box, check its
2. Power not on at AC power source (wall outlet). Check with a different appliance.
3. Power switch not on (either the unit or multiple outlet box).
4. Incorrect voltage selection setting. REFER TO QUALIFIED SERVICE PERSONNEL.

No Sound

1. Volume control turned all the way down on the K2661 or on amplifier or mixer.
2. Amplifier or mixer not turned on.
3. Cabling is not correct; see Chapter 2 of the Musician's Guide, and read about the various
4. MIDI volume has been assigned to a control source which has sent a value of 0. Pressing
Left MIX Output Seems Louder Than Right MIX Output When Used Individually
This is normal. When a cable is plugged into the left MIX output alone, both the left AND the
right audio signals are routed to the jack. When a cable is plugged into the right MIX output
alone, only the right channel audio signal is heard.

Volume Knob Has No Effect

1. Separate outputs are in use; the volume knob does not affect the separate outputs.
2. MIDI volume has been assigned to a control source which has sent a value of 0.
Programs, Setups, Songs, or Other Objects Are Missing
Battery has run down or has been disconnected. If the battery has failed, the message "Battery
voltage is low - X.X volts" (where X.X is less than 3.0) will appear in the display on powerup. All
user data will be permanently lost if this occurs. See Battery Replacement on page 8-2.
No Signal at ADAT In
To use ADAT In, the K2661's ADAT Out cable must also be connected to the sending device.
Since the K2661 must be the "master," the other device(s) must "slave" to it.
8-6
plug.
cable connections you need to make: power, audio, MIDI. There's more about audio
configurations in Chapter 19 of the Musician's Guide. Also check that your amplifier, mixer
and speaker connections are correct.
the Panic soft button will reset all controls, and resolve this problem.