Cisco 675E Hardware Installation Manual page 54

Redundant power system
Table of Contents

Advertisement

Table 3-1
Symptom
Fan (blower)
LED is amber.
One or more DC
Output LEDs are
blinking green.
One or more DC
Output LEDs are
solid amber.
Cisco RPS 675 Redundant Power System Hardware Installation Guide
3-2
LED Indications and Appropriate Action (continued)
Condition
The blower is not
operating properly.
The RPS is
unavailable to the
connected device. It
is either providing
power to another
connected device or a
fault condition exists.
The RPS is in standby
mode.
Chapter 3
Action
The fan is defective. Replace the
RPS 675.
Verify that the RPS is supplying
power to one device. If so, this is a
normal indication and will change
when that external device is again
supplying its own power and you
press the Standby/Active button.
Press the Standby/Active button to
put the RPS into active (or ready)
mode.
Troubleshooting
78-15201-03