For example:
Severity Level
Date/Time
Info
2008-08-06
09:35:07
2008-04
Critical
12:12:05

Viewing an Event Log Saved From SMU

You can save event log data to a file on your network as described in "Saving Log
Information to a File" on page 192.
A saved log file has the following sections:
Contact information and comments
Combined SC event log – All events logged by both controllers.
SC event log for controller A – Events logged by controller A.
SC event log for controller B – Events logged by controller B.
SC error/warning log – Only critical and warning events for both controllers.
The file lists up to 200 events for a single controller or up to 400 events for both
controllers. The events are listed in chronological order; that is, the most recent
event is at the bottom of a section. In the event log sections, the following
information appears:
Event SN – Event Serial Number. The prefix (A or B) indicates which
controller logged the event. This corresponds to the Event Serial Number
column in SMU.
Date/Time – Year, month, day, and time when the event occurred.
Code – Event code that assists service personnel when diagnosing problems.
This corresponds to the Event Code column in SMU.
Sev – I (informational); W (warning); C (critical). This corresponds to the
Severity Level column in SMU.
Ctrlr – A or B indicates which controller logged the event.
Description – Information about the event. This corresponds to the Message
column in SMU.
Event Code
Event Serial Number
33
A29856
65
A29809
Message
Time/date has been
changed
Uncorrectable ECC error
in buffer memory
address 0x0 on bootup
Chapter 7 Troubleshooting Using SMU